Part Number |
General Description |
Package |
RMS on-state current (A) |
Repetitive peak off-state voltage (V) |
Non repetitive surge peak on-state current (A) |
Junction Temperature (°C) |
Quadrants |
Triggering gate current max (mA) (I, II, III) default |
Triggering gate current max (mA) (I, II, III, IV) default |
Rate of decrease of commutating on-state current (A/ms) (@Tj max) |
Rising Ratio Of Off Voltage (V/µs) (@Tj max) |
T1635 |
16A Snubberless™ Triacs |
D2PAK |
16 |
600 |
160 |
125 |
I, II, III |
35, 35, 35 |
- |
8.5 |
500 |
T2550-12G |
1200V 25A Snubberless™ Triac |
D2PAK |
25 |
1200 |
240 |
125 |
I, II, III |
50, 50, 50 |
- |
100 |
2500 |
T810 |
8A logic level Triacs |
D2PAK;DPAK |
8 |
600;800 |
80 |
125 |
I, II, III |
10, 10, 10 |
- |
2.8 |
40 |
BTB16 |
16A standard and Snubberless™ Triacs |
TO-220AB |
16 |
600;800 |
160 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
14;3;7;8.5 |
1000;200;40;400;500 |
T830-8FP |
8 A Snubberless™ Triac |
TO-220FPAB |
8 |
800 |
80 |
125 |
I, II, III |
30, 30, 30 |
- |
10 |
2500 |
TPDVxx40 |
40A high-voltage Triacs |
TOP3 Ins |
40 |
1200;600;800 |
350 |
125 |
I, II, III |
200, 200, 200 |
- |
35 |
500 |
T2550-12T |
1200V 25A Snubberless™ Triac |
TO-220AB |
25 |
1200 |
240 |
125 |
I, II, III |
50, 50, 50 |
- |
100 |
2500 |
BTB08 |
8A standard and Snubberless™ Triacs |
TO-220AB |
8 |
600;800 |
80 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
1.5;3;4.5;5.3;7 |
1000;20;200;40;400 |
Z04 |
4A Triacs |
TO202-3 |
4 |
600;800 |
20 |
125 |
I, II, III, IV |
- |
10, 10, 10, 10;25, 25, 25, 25;3, 3, 3, 3 |
0.5;1;2;5 |
10;100;20;200 |
BTA26 |
25A standard and Snubberless™ Triacs |
TOP3 Ins |
25 |
600;800 |
250 |
125 |
I, II, III;I, II, III, IV |
35, 35, 35;50, 50, 50 |
50, 50, 50, 100 |
13;13.3;22 |
1000;500 |
BTA24 |
25A Snubberless™ Triacs |
TO-220AB Ins |
25 |
600;800 |
250 |
125 |
I, II, III |
35, 35, 35;50, 50, 50 |
- |
13;22 |
1000;500 |
BTB10 |
10A standard and Snubberless™ Triacs |
TO-220AB |
10 |
600;800 |
100 |
125 |
I, II, III |
50, 50, 50 |
- |
7 |
1000 |
BTB41 |
40A standard Triacs |
TOP3 |
40 |
600;800 |
400 |
125 |
I, II, III, IV |
- |
50, 50, 50, 100 |
20 |
500 |
BTA40 |
40A standard Triacs |
RD-91 |
40 |
600;800 |
400 |
125 |
I, II, III, IV |
- |
50, 50, 50, 100 |
20 |
500 |
BTB04-600SL |
4A Snubberless™ Triacs |
TO-220AB |
4 |
600 |
35 |
125 |
I, II, III |
- |
10, 10, 10, 25 |
1.8 |
75 |
T16T |
16A Snubberless™ and logic level Triacs |
TO-220AB Ins |
16 |
600 |
120 |
125 |
I, II, III |
10, 10, 10;20, 20, 20;35, 35, 35 |
- |
16;4;6 |
100;1000;2000 |
BTA20 |
20 A Snubberless™ Triacs |
TO-220AB Ins |
20 |
600;700 |
200 |
125 |
I, II, III |
35, 35, 35;50, 50, 50 |
- |
11;18 |
250;500 |
T25 |
25A Snubberless™ Triacs |
D2PAK |
25 |
600;800 |
250 |
125 |
I, II, III |
35, 35, 35 |
- |
13 |
500 |
T410 |
4A logic level Triacs |
DPAK;IPAK;TO-220AB |
4 |
600;700;800 |
30 |
125 |
I, II, III |
10, 10, 10 |
- |
2 |
40 |
BTA41 |
40A standard Triacs |
TOP3 Ins |
40 |
600;800 |
400 |
125 |
I, II, III, IV |
- |
50, 50, 50, 100 |
20 |
500 |
BTB06 |
6A standard and Snubberless™ Triacs |
TO-220AB |
6 |
600 |
60 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5 |
25, 25, 25, 50;50, 50, 50, 100 |
1.2;2.4;2.7;3.5;5.3 |
1000;20;200;40;400 |
T1610 |
16A logic level Triacs |
D2PAK |
16 |
600;800 |
160 |
125 |
I, II, III |
10, 10, 10 |
- |
3 |
40 |
TXDVxx12 |
12A high-voltage Triacs |
TO-220AB Ins |
12 |
1200;800 |
120 |
125 |
I, II, III |
100, 100, 100 |
- |
30;42.5 |
200;500 |
BTA25 |
25A standard and Snubberless™ Triacs |
RD-91 |
25 |
600;800 |
250 |
125 |
I, II, III;I, II, III, IV |
50, 50, 50 |
50, 50, 50, 100 |
13.3;22 |
1000;500 |
BTA10-600GP |
10 A Triac |
TO-220AB Ins |
10 |
600 |
120 |
125 |
I, II, III, IV |
- |
25, 25, 25, 100 |
2.2 |
30 |
T435 |
4A Snubberless™ Triacs |
DPAK;IPAK;TO-220AB |
4 |
600;700;800 |
30 |
125 |
I, II, III |
35, 35, 35 |
- |
2.5 |
400 |
T835 |
8A Snubberless™ Triacs |
D2PAK;DPAK |
8 |
600;800 |
80 |
125 |
I, II, III |
35, 35, 35 |
- |
4.5 |
400 |
BTA12 |
12A standard and Snubberless™ Triacs |
TO-220AB Ins |
12 |
600;800 |
120 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
1;12;2.9;5.3;6.5 |
1000;20;200;40;400;500 |
BTB26 |
25A standard Triacs |
TOP3 |
25 |
600 |
250 |
125 |
I, II, III, IV |
- |
50, 50, 50, 100 |
13.3 |
500 |
Z00607 |
0.8A standard Triacs |
TO-92 |
0.8 |
600 |
9 |
125 |
I, II, III, IV |
- |
5, 5, 5, 7 |
1.5 |
10 |
T12xx |
12A Snubberless™ Triacs |
D2PAK |
12 |
600;800 |
120 |
125 |
I, II, III |
10, 10, 10;35, 35, 35 |
- |
2.9;6.5 |
40;500 |
T405 |
4A logic level Triacs |
DPAK;IPAK;TO-220AB |
4 |
600;700;800 |
30 |
125 |
I, II, III |
5, 5, 5 |
- |
0.9 |
20 |
BTA06 |
6A standard and Snubberless™ Triacs |
TO-220AB Ins |
6 |
600;800 |
60 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5 |
25, 25, 25, 50;50, 50, 50, 100 |
1.2;2.4;2.7;3.5;5.3 |
1000;20;200;40;400 |
TPDVxx25 |
25A high voltage Triacs |
TOP3 Ins |
25 |
1000;1200;800 |
230 |
125 |
I, II, III |
150, 150, 150 |
- |
20 |
500 |
BTA16 |
16A standard and Snubberless™ Triacs |
TO-220AB Ins |
16 |
600;800 |
160 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
14;3;7;8.5 |
1000;200;40;400;500 |
BTA10 |
10A standard and Snubberless™ Triacs |
TO-220AB Ins |
10 |
600;800 |
100 |
125 |
I, II, III;I, II, III, IV |
35, 35, 35;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
4.4;5.5;9 |
1000;200;400;500 |
BTB24 |
24A standard and Snubberless™ Triacs |
TO-220AB |
25 |
600;800 |
250 |
125 |
I, II, III;I, II, III, IV |
35, 35, 35;50, 50, 50 |
50, 50, 50, 100 |
13;13.3;22 |
1000;500 |
Z01 |
1A Triacs |
SMBflat-3L;SOT-223;TO-92 |
1 |
600;700;800 |
8 |
125 |
I, II, III, IV |
- |
10, 10, 10, 10;25, 25, 25, 25;3, 3, 3, 5;5, 5, 5, 7 |
0.5;1;2;5 |
10;100;20;50 |
BTA08 |
8A standard and Snubberless™ Triacs |
TO-220AB Ins |
8 |
600;800 |
80 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5;50, 50, 50 |
25, 25, 25, 50;50, 50, 50, 100 |
1.5;3;4.5;5.3;7 |
1000;20;200;40;400 |
BTB12 |
12A standard and Snubberless™ Triacs |
TO-220AB |
12 |
600;800 |
120 |
125 |
I, II, III;I, II, III, IV |
10, 10, 10;35, 35, 35;5, 5, 5 |
25, 25, 25, 50;50, 50, 50, 100 |
1;12;3;5.3;6.5;8.5 |
1000;20;200;40;400;500 |
T405Q-600 |
4A sensitive Triacs |
DPAK;IPAK |
4 |
600 |
35 |
125 |
I, II, III, IV |
- |
5, 5, 5, 10 |
1.8 |
10 |